Nortel Networks Network Card DS30 User Manual

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •  
DS30/Station Port Adapter  
Installation Guide  
• • • • • • • • • • • • • • • • • • •  
 
1
DS30/STATION PORT ADAPTER  
REGULATORY APPROVAL  
Table 1. Regulatory Approvals  
TYPE COUNTRY  
SPECIFICATION  
PROCEDURE  
Radiated Canada  
Emissions US  
UK  
ICES-003/CISPR22 Class B  
FCC Part 15/CISPR22 Class B ANSI C63.4  
ANSI C63.4  
EN55022  
ICES-003/CISPR22 Class B  
ANSI C63.4  
ANSI C63.4  
Conducted Canada  
Emissions United States FCC Part 15/CISPR22 Class B ANSI C63.4  
UK  
EN 55022  
ANSI C63.4  
EN50082-1  
Safety  
Canada  
US  
UK  
CSA C22.2 No. 950-95 (CUL)  
UL 1950 edition 3  
EN 60950  
International IEC 950 edition 2  
NOTE  
This equipment has been tested and found to comply with the limits for a Class  
A digital device, pursuant to Part 15 of the FCC Rules. The limits are designed  
to provide reasonable protection against harmful interference when the  
equipment is operated in a commercial environment. This equipment generates,  
uses and can radiate radio frequency energy, and if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely to  
cause harmful interference in which case the user will be required to correct the  
interference at his own expense.  
WARNING  
Use only UL CSA/cUL approved Class 2 Wall Mount  
Power Supply with a rated output of 12VAC.  
DS30/Station Port Adapter  
Installation Guide  
 
2
PRODUCT DESCRIPTION  
Table 2. Product Description  
CONNECTOR RJ-45 Jacks  
INTERFACES  
DS-30 Fiber  
Two RJ-45 jacks each accepting up to  
four TCM Loops  
One female DS-30  
Connector  
Power  
Connector  
fiber optic connector pair  
One barrel jack for internal  
power supply to wall mounted 12 VAC  
power source  
SIZE  
Approx. 9.75” (248 mm) x 5.06” (129 mm) x 1.22”  
(36mm)  
WEIGHT  
POWER  
Estimated 20 ounces (567 grams) includes bezel and  
PCB but not wall-mounted power supply  
Country  
Output/Input Rating  
North America  
United Kingdom  
Australia  
12VAC @ 600mA/110VAC  
12VAC @ 600mA/240VAC  
12VAC @ 600mA/240VAC  
RELIABILITY Mean time before failure (MTBF) target is greater than  
20 years using Mil-Std-217F method TBD reliability  
calculations.  
FUNCTIONAL Multiplexes up to eight Nortel Norstar TCM Loops  
DESCRIPTION (up to 16 voice paths) into one DS-30 fiber optic  
line. Each TCM Loop may include up to two active  
voice/data paths as well as a control signaling path.  
TCM  
Loop  
RJ-45 Connectors  
TCM  
TCM  
Loops Loops  
1-4 5-8  
Status  
LEDs (8) Connector  
AC Power DS30 Fiber  
Connector  
1 4 7  
2 5 8  
3 6  
FIBER  
DS - 30  
KSU 1 - 4 KSU 5 - 8  
LINE POWER FIBER OPTIC  
Fiber Line Status LED  
Figure 1. DS-30/Station Port Adapter  
Installation Guide DS30/Station Port Adapter  
 
3
INSTALLATION  
1. Connect the TCM Loops from the KSU to a male RJ-45 connector  
using the wiring scheme in Figure 2 below. Connect up to 8 TCM  
Loops with TCM Loops 1 to 4 in RJ-45 connector 1 and TCM Loops 5  
to 8 in RJ-45 connector 2.  
2. Insert KSU RJ-45 male connector(s) into the appropriate female RJ-45  
connector in the adapter.  
3. Insert DS-30 fiber connector of fiber line from Applications Module  
into DS-30 Fiber Connector of adapter.  
4. Plug power cord into AC Power Connector.  
5. Plug the adapter power into anAC wall outlet. WARNING: Use only UL  
CSA/cUL approved Class 2 Wall Mount Power Supply with a rated  
output of 12VAC.  
To Adapter  
RJ-45  
To Adapter  
RJ-45  
Connector  
Connector  
Female RJ-45  
JP1  
Female RJ-45  
JP1  
TCM Loops 1-4  
TCM Loops 5-8  
8
7
6
5
4
3
2
1
Pins 1-8  
8
7
6
5
4
3
2
1
Pins 1-8  
Loops 1-4  
4- 3- 2- 1- 1+ 2+ 3+ 4+ Loops 5-8  
8- 7- 6- 5- 5+ 6+ 7+ 8+  
To Norstar KSU  
To Norstar KSU  
Figure 2. TCM Loop RJ-45 Pinout Connections  
DS-30/Station Port Adapter  
Fiber  
Spool  
1
2
3
4
5
6
7
8
FIBER  
DS  
-
30  
KSU  
1
-
4
KSU  
5
-
8
LINE POWER FIBER OPTIC  
Norstar KSU  
Applications Module  
Figure 3. Installation Diagram  
DS30/Station Port Adapter  
Installation Guide  
 
4
TROUBLESHOOTING  
Table 3. Troubleshooting Guide  
SITUATION  
Fiber Line LED light is  
flashing  
INDICATION LINK  
ACTION  
Power on  
Invalid Check fiber  
connection between  
units  
Fiber Line LED light is off  
Fiber Line LED light is on  
No Power  
Power on  
Invalid Check power source  
Valid  
None  
None  
TCM Loop LED port light  
is on  
TCM Loop LED port light  
is off  
Active port  
connection  
Inactive port  
connection  
Valid  
Invalid Check corresponding  
port connection  
NOTE: Timing master uses highest numbered TCM Loop connected  
port to synchronize DS-30 link.  
The DS30/Station Port Adapter is compatible with ACCESS 2.6  
ver. 6.52 and higher within application products running on the  
NAM II platform. Systems with previous versions of ACCESS  
should obtain an appropriate upgrade.  
TCM Loop 1  
1 4 7  
Fiber Line  
2 5 8  
FIBER  
LINE  
3 6  
Figure 4. Close-upView of LEDs  
Installation Guide  
DS30/Station Port Adapter  
 

Minolta Digital Camera XG 1 Body Only User Manual
MTD Trimmer CC4125 CC4175 User Manual
Multiquip Power Roller R2000H User Manual
National Instruments Network Card NI 9144 User Manual
NEC Projector SX10000 User Manual
Nortec Humidifier NHDI User Manual
Novatel Car Satellite TV System 15a User Manual
Novatel Car Satellite TV System GM 14915098 User Manual
Paradyne Appliance Trim Kit 727 User Manual
Patton electronic Marine Battery RS 449 422 to V35 User Manual